Back



Download CV as PDF
 

Position:

NDT engineer

Personal details:

 

Name surname:
Birth date:
Nationality:
Spoken languages:
Razvan Hristu
1967-12-30
Romanian
English

Other details:

 

Key qualifications:
NDT, Quality
CV created:
2012-01-11

Experience:

 

Company:
TEKNICA Oil Co. UK, CRADDOCK Eng. UK (from: Feb-2006 - present)
Position:
NDT Inspector (RT, UT, MPI)
More information:
Project 1018-103A
Location 103A, SAHARA Desert, LIBYA
42”ODx19 Gas Transmission Pipeline to Coastal Network
CLIENT ZUEITINA OIL Co., Libya
Contractor CPPE (Chinese Petroleum Pipeline Eng.)
Welding Tech. 5G-FCAW (MIG/MAG), V-type bevel, SMAW - repairs only
Standards API 5LX65, API-1104, EN473
RT (100%) Specifications
- crawler technique, SWSI exposure ;
- panoramic head X-ray tube model, Freon-cooling ;
- 5mA, 300kV, 5x1.2 focal spot size ;
UT (repairs only) Specifications
- DAC/6dB drop method used for dimensional evaluation ;
- 45, 60, 70 deg angular probes, shear waves, used for welds examination
and normal incidence, compression waves, used for lamination flaws control
and/or thickness measurements.

I was responsible, on behalf of CLIENT, for everything involving and/or related
to NDT activity, meaning procedures, materials, performing, equipment’s calibration, assessment and final reports. Also, as Inspector, I provided support, following the procedures, for the Rights of Way preparation, stringing and related jobs.


CAD Draftsman (piping) In charge with producing of Isometrics for Gas Skid, Manifolds, GL vessels,
Crude Oil Flow Tanks, pipelines, pipe tracks, flare lines, using AutoCAD,
Auto-Sketch, required for Corrosion monitoring (UT thickness gauging)
All the locations are within desert (Libya), Sabah, Fidda, Zella, 103A, 103D,
Terminal - Coastal Network, Client - Zueitina Oil Co.
Company:
SAIPEM Spa (ENI Group), ITALY (from: Jan-2002 - Jan-2004)
Position:
AUT Technician (Automated Ultrasonic Testing – Phased Array & TOFD)
More information:
- scanning technology based on Pipe WIZARD (RD Tech, CANADA)
(Welds Inspection using Zone discrimination Array and Real-Time Display)
and Phased Array Systems, fully computerized ;
- the system uses 2 phased array probes (shear waves),
based on 120 elements (60-upstream, 60-downstream), which generates
the focal beam, TOFD – Time Of Flight Diffraction using a wide angle beam
(compression waves), 2 gates Echo Amplitude and TOF (Time Of Flight) .

Project TTM Trans Thailand Malaysia
Location offshore Thailand Gulf, South China Sea
34”ODx19mm Gas Transmission Pipeline, API 5LX65
CLIENT GREEN STREAM
Contractor SAIPEM (ENI Group) ITALY, barge - SEMAC1
CLASS DNV (DET NORSKE VERITAS)
Welding Tech. 5G-GMAW (PRESTO/PASSO), J-type bevel, SMAW - repairs

TTM project - I have worked for the Contractor as scanner/NDT technician, checking the pipeline welds using AUT – Pipe WIZARD technology
and manual UT/MPI, in case of cutting-out and/or excavations and also
for wall thickness and coating gauge required by Class .
The project consisted in laying down on the bottom of THAILAND Gulf
of 340Km length gas pipeline, all the welding (SMAW/GMAW) and
NDT procedures being authorized by SAIPEM, CLASS and CLIENT.
Company:
DAEWOO HEAVY IND. Shipyard, ROMANIA (from: Feb-1996 - Apr-2002)
Position:
NDT Field engineer - QA/QC Dept. , New Building/Ship Repair
More information:
UT Lab Specifications
Ultrasonic Testing - SONIC 1200S, PANAMETRICS EPOCH III/4B, DMS KRAUTKRAMER
- 45, 60, 70 degrees angular probes, shear waves, used for welds examination
and normal incidence, compression waves, used for lamination flaws control
and/or thickness gauges ;
- DAC/6dB drop method used for dimensional evaluation ;
- crystal dimensions for usual investigation 500mm2/25mm thickness
and 125mm2/15mm for critical investigation .
RT Lab Specifications
Radiographic Testing - Gamma isotopes 192-Ir, 40Ci / 60-Co, 60Ci, closed sources,
GDP-U5 container, X-ray generators, 300kV, 5mA ,air-cooling;
- AGFA VACUPAC D5/D7 film sensitivity, 1.8-3.0 black density ;
- radiographic techniques, time and geometry exposure calculating ;
- radiographic assessment,
the assessment criteria following the Classification Society’s rules ;
- NDT examination and thickness gauges, performed to shell plates, pipelines,
engine support, longitudinal and transverse stiffener and some other stress
steel structures (different parts of the cranes, mobile bridges/conveyers),
couplings and block sections in every stage, erection, pre-erection.
QA/QC related activities
- internal NDT procedure conceiving and elaborating, in fact it’s a common
denominator based on different consecrated rules.
- internal personnel training - level 1 and welders authorizing ;
- materials estimation/calculation for diverse related works/forward projects,
serving to Marketing Dept. ;
- performing QC inspection requirement sheets, works surveillance.




CAD Draftsman
- NDT map drawings (AutoCAD), based on seam lines arrangement,
shell expansion and block division plans, certified by Class ;
- I had to calculate and set the NDT distribution points, according to Class
specifications, to consider all the differences between our provider’s
plate panels dimensions and the Client’s class-ship drawings, to modify almost
everything, frames intervals, seam lines, couplings, according to our
dimensions, and to get the projections, Top/Side/Transverse 2D views using
AutoCAD, shell, transverse/longitudinal bulkheads..

Education:

 

Jan-1987 - Feb-1992
Organization: Technological Physics Faculty, BUCHAREST University, Romania
More information: Bachelor degree – engineer

Computer skills:

MathCAD, AutoCAD, Auto-Sketch, Corel DRAW suite, FoxPro
MS OFFICE suite (WORD, EXCEL, ACCESS, VISUAL, PROJECT)
IT service - hardware support, network administrating and OS(XP) configuration.

Other skills/competences:

REFERENCES DAEWOO Heavy Ind. Shipyard, Mangalia, Constanta, Romania
Contact Petre Iulian, QA/QC Dept. Manager
Tel. +40 241 706200 (dispatch center, QA/QC requires extension)
Email hr@dmhi.ct.ro (Personnel Dept.)
Web www.dmhi.ct.ro (more information, updated)

SAIPEM Spa. (ENI Group), Cortemaggiore, Piacenza, Italy
Contact Lorenzo Pasquali, NDT Supervisor
Mobile / Tel. +39 335 8259465 / +39 0523 834229
Email lorenzo.pasquali@saipem.eni.it

Teknica Oil Services Ltd.
Tel. +44 020 7413 9600
Branch Office Tripoli, Libya
Contact Zlitni, Office Manager
Tel. 0218 21 335 0515
Email / Web mail@teknica.uk.co.uk / www.teknica.uk.co.uk

Craddock Ltd. UK
Contact Gray Davidson, Manager Craddock UK
Tel./Fax +44 1358 723770 / +44 1358 723780
Web/Email www.craddock.biz / g.davidson@craddock.biz
Craddock, Tripoli, Libya
Contact Branch Office
Tel./Fax +218 21 4836 552 / +218 21 4837 572
Email ehsi@craddock.biz

Certificates: